Rating input voltage | 2000 VA / 1200 W |
Rating input frequency | 60/50Hz (auto sensing) |
Input phase | Single phase |
Input socket | With Fuse |
Cold Start (0 to 100% load) | Press the ON/OFF Switch |
Input Range (220V) | 140-300 |
Rating output(VA) | 2000 |
Rating output (W) | 1200 |
Power factor | 0.6 |
Rating output voltage (V) | 220 |
Waveform | Battery mode (simulated sine wave), AC mode(sine wave) |
AC Voltage Regulation | ±10% (Battery mode) |
Rear output socket | 4 x Universal – Battery backup |
Waveform | Simulated Sine Wave (Battery mode) |
Line Mode | Synchronize with the utility |
Rating frequency | 60Hz or 50 Hz ± 1 Hz |
Battery Mode | Yellow flashing |
Short circuit protection Line Mode | Fuse & Firmware protection |
Short circuit protection Battery Mode | Firmware Protection |
Overload protection Line Mode | 110%±5%; Go to fault mode Line Mode after 5 minutes, 120%±5%; Go to fault mode immediately. |
Overload protection Battery Mode | 110%±5%; Shutdown after 5 seconds, 120%±5%, Shutdown immediately |
Indicators AC mode | Green Lighting |
Indicators Battery Mode | Yellow Flashing |
Indicators Fault | Red Lighting |
Alarm Battery Mode | Sounding every 10 Seconds |
Alarm Low Battery | Sounding every Second |
Alarm Overload | Sounding every 0.5 second |
Alarm Fault | Continuously sounding |
Full Protection | Overload, discharge, and Overcharge protection |
Transfer Time | Typical 2-6ms, 10ms max. |
Transfer Time | Typical 2-6ms, 10ms max. |
Communication Interface | Optional RS232/RJ11 |
Battery and runtime Rating | 2 X 12V/9AH |
Recharge time – Typical | 6-8 hours recover to 90% capacity |
Charge current | About 1A at normal mode. |
Dimension, W X H X D (cm) | 22.5 X 12.5 X 39 |
Net Weight (kgs) | 12.7KGS |
Humidity | 0-90 % RH @ 0- 40°C (non-condensing) |
Noise Level | Less than 45dB |
Compatible with OS | Supports Windows® 2000/2003/XP/Vista/2008/7 |