Image 1 of 3
APCModel AP8858EU3
APC AP8858EU3 power distribution unit (PDU) 20 AC outlet(s) 0U
Available to order
APC. Available from OfficeLand with nationwide delivery; request a quote for pricing.
At a glance
- Output connections
- 18x IEC 320 C13 2x IEC 320 C19
- Nominal output voltage
- 230 V
- Certification
- CSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS, REACH
- Total carbon footprint (kg of CO2e)
- 13349.44
- AC outlet types
- C13 coupler, C19 coupler
- Input connection type
- IEC 309 16A 2P+E
Request a quote for pricing
Answered within one business day. Volume pricing available.
Nationwide delivery, installed in Lagos. Lead times Manufacturer warranty, claims handled by us. How it works Authorised reseller, SON certified. Quotes answered within one business day.
Overview
APC AP8858EU3 power distribution unit (PDU) 20 AC outlet(s) 0U is a APC product with a certification of CSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS, REACH and a cable length of 3 m. The details below are drawn from the manufacturer specification and are what to check against your own requirement before requesting a quote.
Certification is CSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS, REACH. Cable length is 3 m. Total carbon footprint (kg of CO2e) is 13349.44. Mounting is Vertical. Output connections is 18x IEC 320 C13 2x IEC 320 C19. Nominal output voltage is 230 V. Weight is 2.93 kg. Maximum input current per phase is 16 A. Each of these is listed again in the specification table, so nothing here has to be taken on trust.
Warranty: 2 years. Ask us if you need a different configuration - we quote against the specification you actually need rather than the one on the box.
Specifications
| Output connections | 18x IEC 320 C13 2x IEC 320 C19 |
|---|---|
| Nominal output voltage | 230 V |
| Certification | CSA C22.2 No. 60950,IEC 60950,METI Denan,UL 60950-1,VDE RoHS, REACH |
| Total carbon footprint (kg of CO2e) | 13349.44 |
|---|
| AC outlet types | C13 coupler, C19 coupler |
|---|---|
| Input connection type | IEC 309 16A 2P+E |
| Width | 56 mm |
|---|---|
| Depth | 44 mm |
| Height | 902 mm |
| Weight | 2.93 kg |
| Package width | 162 mm |
|---|---|
| Package depth | 107 mm |
| Package height | 1124 mm |
| Package weight | 4.92 kg |
| Operating temperature (T-T) | 5 - 45 °C |
|---|---|
| Storage temperature (T-T) | -25 - 65 °C |
| Operating relative humidity (H-H) | 5 - 95% |
| Storage relative humidity (H-H) | 5 - 95% |
| Cable length | 3 m |
|---|
| Monitoring | Current, Power, Voltage |
|---|
| AC input frequency | 50 - 60 Hz |
|---|---|
| Maximum power | 3680 W |
| Maximum total current draw per phase | 16 A |
| Load capacity | 3680 VA |
| Maximum input current per phase | 16 A |
| AC outlets quantity | 20 AC outlet(s) |
|---|---|
| Power plug | IEC309 |
| PDU types | Metered |
|---|---|
| Rack capacity | 0U |
| Mounting | Vertical |
Warranty
2 years